Skip to content
2009

Domestic Air Ingress Mitigations

Abstract

This project will help to provide assurance to UK Gas Distribution Network Operators (GDNOs) and wider industry on the safe design of domestic gas appliances in a future where hydrogen is being distributed in network pipelines. A risk to the normal safe operation of appliances under 100% hydrogen operation exists where a flammable hydrogen/air mixture is supplied to the appliance, creating the potential for flashback to occur within the gas installation pipework. This work will provide assurance that domestic appliances designed to operate on 100% hydrogen are designed in a way which do not enable flashback to occur.

The project will also investigate the long-term feasibility of installing an auto-locking Emergency Control Valve (ECV) at the end of 100% hydrogen networks to ensure that any reinstatement of supply after a period of isolation can only be undertaken by a competent gas engineer.

The project will develop new learning in relation to the validation of domestic hydrogen appliance design, feasibility of auto-locking ECVs to be installed on the gas network, as well as developing a better understanding of the impact that non-metallic material selection has on permeation rates.